Specifications - DrizAir 1400

<< Click to Display Table of Contents >>

Owner's Manual >

Specifications - DrizAir 1400

Previous pageReturn to chapter overviewNext page

Name

DrizAir 1400 #127727 / #127890

Water removal AHAM

@80°F/60% RH (26.7°C/60%RH)

64 pts. | 30.3 L/day

Water removal saturation
@90°F/90% RH (32.2°C/90%RH)

129.9 pts. | 59.1 L/day

Process air (max.)

220 CFM | 374 CMH

Max. Oper. Temp.

104°F | 40°C

Dimensions (W × H × D)

20 x 19.5 x 16.0 in. | 50.8 × 49.5 × 40.6 cm

Use Weight (w/ cord & hose)

65 lbs. | 29.5 kg

Amps
@80°F/60% RH) 26.7°C/60%RH

4.7A

Input Current
(104°F/35%RH | 40°C/35%RH)

7.1A

Power

115V, 60Hz, 541W

Refrigerant

R32, 0.241 kg (8.5 oz)

Max. use altitude

10,000 ft. | 3 km

Operating range

33°F–100°F | 1°C–38°C

Noise level (avg.)

63 dB

Drain hose

40 ft. | 12.2 m

Power cord

25 ft. | 7.6 m

Construction

Injection-molded shell

Safety

Conforms to UL STD 60335-1 & 60335-2-40

Certified to CSA STD. C22.2 NO. 60335-1 & CO335-2-40

Specifications are subject to change without notice. Some values may be approximate.  

*Fan speed varies automatically for optimized performance.