<< Click to Display Table of Contents >> Control panel - DrizAir 1200 |
Press the “on” button on the touchpad.
The Touchpad on DrizAir dehumidifiers has one display and four keys. The normal display messages are
DEHUMIDIFIER OFF |
CMPRSR DELAY |
DEHUMIDIFIER ON |
PUMP PURGING |
TOTAL HRS |
DEFROST ON |
JOB HRS |
GET SERVICE ERXX |
When the unit is first connected to AC power, the touchpad display will cycle continuously through three messages: DEHUMIDIFER OFF, TOTAL HOURS, and JOB HOURS.
ON-OFF. Press the ON-OFF key to turn the unit on or off. When turning the machine on, usually the display reads CMPRSR DELAY and performs a numeral count down from a maximum of 60 seconds to 0. The compressor delay gives the machine time to warm up (when needed). If you don’t see a compressor delay countdown, the machine is ready to go. Once the unit completes the CMPRSR DELAY, the display reads DEHUMIDIFIER ON, and continues to cycle between TOTAL HOURS, JOB HOURS and DEHUMIDIFIER ON.
Press the ON-OFF key again to turn the unit off. The display will read DEHUMIDIFIER OFF.
DISPLAY. Press the DISPLAY key to stop the display at DEHUMIDIFER ON or OFF, TOTAL HOURS, or JOB HOURS as it cycles. Press DISPLAY again to re-start the display cycle.
CAUTION: While in the change-language mode, pressing other keys can change the programming of the machine. Do NOT press other keys you’re not instructed to press.
Use the DISPLAY key to change the display language.
Follow these steps:
1.Unplug the unit.
2.While holding down the DISPLAY key, plug the unit in. The display reads ENGLISH.
3.To change to FRANCAIS, DEUTSCH, or ESPANOL, press the DISPLAY key or the CLEAR key.
4.When the desired language is shown in the display, unplug the unit, and the language is set.
CLEAR. Press the CLEAR key to reset the JOB HOURS
1.As the display cycles between DEHUMIDIFIER ON, JOB HOURS, and TOTAL HOURS, press the DISPLAY key when JOB HOURS appears on the screen. That will make the display read JOB HOURS steadily.
2.Then press the CLEAR key to re-set the numerals to 00000.
3.Press DISPLAY again to re-start the display cycle.
NOTE: the TOTAL HOURS reading cannot be re-set.
PURGE. Press the PURGE key to empty water from the pump reservoir. During normal operation, the pump purges automatically every six minutes, or whenever the reservoir is full. The display will read PUMP PURGING with a numeral countdown. To purge the pump manually:
1.Turn the power off using the OFF key, and let the unit sit plugged in for about 10 minutes. This allows water to drip from the coils and collect in the drip pan.
2.Press PURGE to remove residual water.
During normal operation, the temperature sensor detects frost forming on the coils, causing a defrost cycle to start. The display will read DEFROST ON. Dehumidification stops during the defrost cycle. When the unit completes the cycle, the display returns to DEHUMIDIFIER ON.
If the 1200’s onboard diagnostics discover a problem, the unit will display “GET SERVICE,” followed by "ER” and a numeral from 01 to 09. If this message appears, first follow these steps:
1.Unplug the unit and then plug it back in. This may re-set the electronics.
2.If the error message reappears, try the solution (if one is listed) in the “Error and Warnings” section.
3.If the error message still appears, please contact the Dri-Eaz Service Department at 888‑867‑3235.