Specifications - LGR 6000Li

<< Click to Display Table of Contents >>

Owner's Manual >

Specifications - LGR 6000Li

Previous pageReturn to chapter overviewNext page

Name

LGR 6000Li 103614 (F600)

Water removal AHAM

@80°F/60% RH (26.7°C/60%RH)

100 pts. | 47.3 L / day

Water removal saturation
@90°F/90% RH (32.2°C/90%RH)

219 pts. | 103.6 liters / day

Water removal low grain
@80°F/20% RH (26.7°C/20%RH)

9 pts. | 4.3 liters / day

Process air (max.)

320 CFM | 544 CMH

Max. Oper. Temp.

104°F | 40°C

Dimensions (W × H × D)

32.1 × 19.8 × 20.0 in. | 81.5 × 50.3 × 50.8 cm

Use Weight (w/ cord & hose)

99 lbs. | 44.9 kg

Amps
@80°F/60% RH) 26.7°C/60%RH

6.5A

Input Current
(104°F/35%RH | 40°C/35%RH)

7.8A

Power

115V, 60Hz, 748W

Refrigerant

R32, 0.496 kg (17.5 oz)

Max. use altitude

10,000 ft. | 3 km

Operating range

33°F–100°F | 1°C–38°C

Noise level (avg.)

53 dB

Drain hose

40 ft. | 12.2 m

Power cord

25 ft. | 7.6 m

Construction

Rotomolded shell

Safety

Conforms to UL STD 60335-1 & 60335-2-40

Certified to CSA STD. C22.2 NO. 60335-1 & CO335-2-40

Specifications are subject to change without notice. Some values may be approximate.  

*Fan speed varies automatically for optimized performance.